How many kWh will solar panels produce where you are? This atlas gives the long-term average solar irradiation, peak sun hours, and PV output per kWp for every regency and city in 38 provinces, with monthly profiles. Sources and calculations are open in the methodology section, so you can check the numbers yourself.
Pick a regency or city on the map or in the search box, or enter your own measured irradiation, then set the PV capacity. The formula is shown under the result.
Selected: Kota Bandung · PSH 4.81 kWh/m²
Example: 6 panels × 550 Wp = 3.3 kWp.
Losses from heat, cables, inverter, dust. Typically 0.75–0.82.
Per day
11.3kWh
Per month
343kWh
Per year
4,113kWh
3.0 kWp × 4.81 h × 0.78 = 11.3 kWh per day (annual average; each month uses that month’s irradiation).
Cross-check: the Solargis model (PVOUT) for Kota Bandung, with panels facing the equator at the optimum tilt, estimates 11.7 kWh per day for 3.0 kWp. The difference comes from panel tilt and loss assumptions.
Want to know how many panels fit on your roof? Draw your roof in the Roof Simulation.
| # | Region | PSH | kWh/kWp/day |
|---|---|---|---|
| 1 | Sabu Raijua RegencyEast Nusa Tenggara | 5.82 | 4.71 |
| 2 | Rote Ndao RegencyEast Nusa Tenggara | 5.72 | 4.63 |
| 3 | Pasuruan CityEast Java | 5.74 | 4.61 |
| 4 | Probolinggo CityEast Java | 5.68 | 4.57 |
| 5 | Kupang CityEast Nusa Tenggara | 5.59 | 4.53 |
| 6 | Denpasar CityBali | 5.58 | 4.52 |
| 7 | Malaka RegencyEast Nusa Tenggara | 5.65 | 4.51 |
| 8 | Timor Tengah Selatan RegencyEast Nusa Tenggara | 5.58 | 4.50 |
| 9 | Flores Timur RegencyEast Nusa Tenggara | 5.54 | 4.47 |
| 10 | Lembata RegencyEast Nusa Tenggara | 5.56 | 4.47 |
| # | Region | PSH | kWh/kWp/day |
|---|---|---|---|
| 514 | Deiyai RegencyCentral Papua | 3.69 | 2.94 |
| 513 | Nduga RegencyHighland Papua | 4.12 | 3.34 |
| 512 | Kepulauan Yapen RegencyPapua | 4.13 | 3.34 |
| 511 | Yahukimo RegencyHighland Papua | 4.10 | 3.34 |
| 510 | Banjarnegara RegencyCentral Java | 4.13 | 3.38 |
| 509 | Kolaka Utara RegencySoutheast Sulawesi | 4.24 | 3.40 |
| 508 | Manokwari RegencyWest Papua | 4.30 | 3.42 |
| 507 | Manokwari Selatan RegencyWest Papua | 4.25 | 3.43 |
| 506 | Samarinda CityEast Kalimantan | 4.33 | 3.44 |
| 505 | Maluku Tengah RegencyMaluku | 4.22 | 3.45 |
Area-weighted averages. Province and regency pages are in Indonesian.
| Province | Regencies/cities | PSH (kWh/m²/day) | kWh/kWp/day | kWh/kWp/year |
|---|---|---|---|---|
| Aceh | 23 | 4.55 | 3.67 | 1,339 |
| North Sumatra | 33 | 4.55 | 3.65 | 1,333 |
| West Sumatra | 19 | 4.50 | 3.62 | 1,321 |
| Riau | 12 | 4.52 | 3.59 | 1,312 |
| Riau Islands | 7 | 4.53 | 3.61 | 1,319 |
| Jambi | 11 | 4.46 | 3.56 | 1,301 |
| South Sumatra | 17 | 4.62 | 3.69 | 1,348 |
| Bangka Belitung Islands | 7 | 4.49 | 3.59 | 1,310 |
| Bengkulu | 10 | 4.70 | 3.77 | 1,377 |
| Lampung | 15 | 4.62 | 3.71 | 1,354 |
| Jakarta | 6 | 4.62 | 3.70 | 1,351 |
| West Java | 27 | 4.70 | 3.80 | 1,387 |
| Banten | 8 | 4.53 | 3.65 | 1,332 |
| Central Java | 35 | 4.92 | 3.97 | 1,448 |
| Yogyakarta | 5 | 5.11 | 4.12 | 1,505 |
| East Java | 38 | 5.08 | 4.10 | 1,495 |
| West Kalimantan | 14 | 4.64 | 3.70 | 1,352 |
| Central Kalimantan | 14 | 4.63 | 3.69 | 1,345 |
| South Kalimantan | 13 | 4.57 | 3.64 | 1,329 |
| East Kalimantan | 10 | 4.53 | 3.61 | 1,319 |
| North Kalimantan | 5 | 4.66 | 3.75 | 1,370 |
| Bali | 9 | 4.83 | 3.91 | 1,428 |
| West Nusa Tenggara | 10 | 5.15 | 4.18 | 1,526 |
| East Nusa Tenggara | 22 | 5.31 | 4.29 | 1,566 |
| North Sulawesi | 15 | 4.72 | 3.80 | 1,387 |
| Gorontalo | 6 | 4.94 | 3.96 | 1,445 |
| Central Sulawesi | 13 | 4.67 | 3.75 | 1,369 |
| West Sulawesi | 6 | 4.78 | 3.84 | 1,401 |
| South Sulawesi | 24 | 4.81 | 3.86 | 1,408 |
| Southeast Sulawesi | 17 | 4.72 | 3.78 | 1,380 |
| Maluku | 11 | 4.56 | 3.66 | 1,337 |
| North Maluku | 10 | 4.71 | 3.77 | 1,378 |
| Papua | 9 | 4.68 | 3.74 | 1,366 |
| West Papua | 7 | 4.55 | 3.64 | 1,328 |
| Southwest Papua | 6 | 4.65 | 3.73 | 1,360 |
| South Papua | 4 | 4.48 | 3.58 | 1,307 |
| Central Papua | 8 | 4.45 | 3.62 | 1,321 |
| Highland Papua | 8 | 4.33 | 3.55 | 1,296 |
Average daily irradiation per month, area-weighted.
| Month | kWh/m²/day |
|---|---|
| Jan | 4.43 |
| Feb | 4.67 |
| Mar | 4.83 |
| Apr | 4.79 |
| May | 4.57 |
| Jun | 4.32 |
| Jul | 4.36 |
| Aug | 4.63 |
| Sep | 4.93 |
| Oct | 4.95 |
| Nov | 4.67 |
| Dec | 4.43 |
Solar PV (photovoltaic) panels turn light into electricity. A complete system with panels, inverter, cabling and, if needed, a battery is called a PLTS in Indonesia. Panel ratings in Wp or kWp refer to standard test conditions: 1,000 W/m² of sunlight and a 25 °C cell. Those conditions are rare on a real roof, so real output is always calculated from the irradiation at the site.
The practical formula used by solar designers:
daily output (kWh) = capacity (kWp) × PSH (h) × performance ratio
Performance ratio (PR) sums up every loss between the sunlight that lands and the electricity you use: heat (each 1 °C above 25 °C cuts crystalline cell power by about 0.35–0.45%), cables, inverter efficiency, dust, and module mismatch. In the tropics it is usually 0.75–0.82; the calculator above uses 0.78, the same as the Batari Roof Simulation.
Example for Bandung City: PSH 4.81 h. A 3 kWp system produces 3 × 4.81 × 0.78 = 11.3 kWh per day, about 4,108 kWh per year. The Solargis model for the same location, with panels at the optimum tilt of 11°, gives 11.7 kWh per day. The two methods usually differ by a few percent; real output then depends on shading, roof direction and panel cleanliness. Full data for Bandung City (in Indonesian).
Batari monitors installed customer systems through its monitoring app. We plan to compare that real production with the atlas region by region and will add the results to this page once there is enough data.
The atlas gives regional figures. The Batari team calculates for your address, roof and electricity use, including a backup battery if outages are frequent.
Solar PV (photovoltaic) is solar panel technology that converts sunlight directly into direct current, which an inverter turns into household electricity. In Indonesia the system is called PLTS (Pembangkit Listrik Tenaga Surya). How much electricity it produces depends heavily on the solar irradiation at the site, which this atlas shows for every regency and city.
Multiply the PV capacity (kWp) by the daily irradiation in kWh/m²/day (equal to peak sun hours) and the system performance ratio. Example: 3 kWp × 4.5 h × 0.78 = 10.5 kWh per day.
The area-weighted average is 4.63 kWh/m² per day, or 4.6 peak sun hours. The range is roughly 3.5 to 6 hours depending on the region.
Irradiance is solar power at one moment (W/m²), peaking around 1,000 W/m² on a clear midday. Irradiation is energy accumulated over a period (kWh/m² per day or per year). PSH (peak sun hours) is daily irradiation expressed as hours of 1,000 W/m² sunshine; the number equals kWh/m²/day.
The data come from the Solargis satellite model (Global Solar Atlas), validated against ground stations in many countries. For annual averages the uncertainty is typically about 4–8%, more in cloudy mountain areas. Shade from trees or buildings at your site is not included, so a site survey is still needed before installing solar.
Yes. Panels capture diffuse light that passes through clouds, just less of it. The monthly data on each region page already account for the rainy season, so you can see the output in the weakest month.
See also: Blackout in Indonesia today · Roof Simulation